A1 - Grubicka Joanna PB - OWN N2 - It is no exaggeration to say that the PN-IEC 61124 standard is inapplicable in many branches e.g. electronic industry. It is because PN-IEC 61124 assumes failure rate to be constant in time. This paper rejects this assumption and presents mathematical foundation of an alternative of PN-IEC 61124 applicable in electronic industry. L1 - http://lib.psnc.pl/Content/720/10.12921_cmst.2010.16.02.135-139_Grubicka.pdf L2 - http://lib.psnc.pl/Content/720 CY - PoznaƄ PY - 2010.09.27 ER - UR - http://lib.psnc.pl/dlibra/docmetadata?id=720